FTB-150-ACCESS (E3)
|
|
°
Wavelength (nm) : 1310 ± 20/1550 ± 20
|
|
° Dynamic range at 10 µs (dB) : 35/34
|
|
° Dynamic range at 20 µs (dB) : 37/35
|
|
° Event dead zone (m) : 1/1
|
|
° Attenuation dead zone (m) : 4.5/5
|
|
|
FTB-150-FTTx (E4, E13, E14)
|
|
°
Wavelength (nm) : 1310 ± 20/1490 ± 10/1550 ± 20/1625 ± 10
|
|
° Dynamic range at 10 µs (dB) : 38/34/37/35
|
|
° Dynamic range at 20 µs (dB) : 39/35/38/36
|
|
° Event dead zone (m) : 1/1/1/1
|
|
° Attenuation dead zone (m) : 4.5/5.5/5/5
|
|
|
FTB-150-METRO (E5)
|
|
°
Wavelength (nm) : 1310 ± 20/1550 ± 20
|
|
° Dynamic range at 10 µs (dB) : 40/38
|
|
° Dynamic range at 20 µs (dB) : 41.5/39.5
|
|
° Event dead zone (m) : 3/3
|
|
° Attenuation dead zone (m) : 10/15
|
|
|
FTB-150-METRO (E10)
|
|
°
Wavelength (nm) : 1310 ± 20/1550 ± 20/1625 ± 10
|
|
° Dynamic range at 10 µs (dB) : 41/40/38
|
|
° Dynamic range at 20 µs (dB) : 42.5/41.5/39.5
|
|
° Event dead zone (m) : 3/3/3
|
|
° Attenuation dead zone (m) : 8/10/10
|
|
|
FTB-150-LH k (E7)
|
|
°
Wavelength (nm) : 1310 ± 20/1550 ± 20
|
|
° Dynamic range at 10 µs (dB) : 43.5/41.5
|
|
° Dynamic range at 20 µs (dB) : 45/43
|
|
° Event dead zone (m) : 3/3
|
|
° Attenuation dead zone (m) : 10/15
|
|
|
FTB-150-ACCESS/FTB-150-FTTx
|
|
°
Distance range (km) : 1.25, 2.5, 5, 10, 20, 40, 80, 160, 260
|
|
° Pulse width (ns) : 5, 10, 30, 100, 275, 1000, 2500,
|
|
° Linearity (dB/dB) : ±0.03
|
|
° Loss threshold (dB) : 0.01
|
|
° Loss resolution (dB) : 0.001
|
|
° Sampling resolution (m) : 0.04 to 5
|
|
° Sampling points : Up to 128 000
|
|
° Distance uncertainty l (m) : ±(0.75 + 0.0025 % x distance)
|
|
° Measurement time : User-defined (60 min maximum)
|
|
° Real-time refresh (s) : Guaranteed: ≤ 0.4 ||| Typical: ≤ 0.3
|
|
° Stable source output power m (dBm) : –8 (–ACCESS), –4.5 (–FTTx)
|
|
° Visual fault locator (optional) : Laser, 650 nm ± 10 nm CW, typical Pout in 62.5/125 µm: 3 dBm (2 mW)
|
|
|
FTB-150-METRO/FTB-150-LH
|
|
°
Distance range (km) : 1.25, 2.5, 5, 10, 20, 40, 80, 160, 260
|
|
° Pulse width (ns) : 10, 30, 100, 275, 1000, 2500,
|
|
° Linearity (dB/dB) : ±0.05
|
|
° Loss threshold (dB) : 0.01
|
|
° Loss resolution (dB) : 0.001
|
|
° Sampling resolution (m) : 0.08 to 5
|
|
° Sampling points : Up to 52 000
|
|
° Distance uncertainty l (m) : ±(1 + 0.0025 % x distance)
|
|
° Measurement time : User-defined (60 min maximum)
|
|
° Real-time refresh (s) : ≤ 1
|
|
° Stable source output power m (dBm) : –5
|
|
° Visual fault locator (optional) : Laser, 650 nm ± 10 nm CW, Pout maximum: ≤ 800 µW
|
|